Unmanaged Ethernet Switch(PoE)
• Multiple working modes to address your business needs: Default(Normal mode), VLAN(Secure mode), EXTEND(Surveillance mode)
• Support port traffic control
• Support for secure mode, all downlink ports can communicate only with uplink ports
• Up to 250m transmission distance on surveillance mode
• Support buffer optimization
• All metal housing, safe and reliable
NSW2020-16T1GT1GC-POE-IN | ||||||||
Hardware Specification | ||||||||
Ports Type | 16×100Mbps PoE ports (RJ45)+ 1×1000Mbps Gigaethernet ports +1×1000Mbps Combo ports | |||||||
Standards | IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3ab, IEEE802.3x, IEEE802.3af, IEEE802.3at, IEEE802.3az | |||||||
Switching capacity | 7.2 Gbps | |||||||
Forwarding performance | 5.36Mpps | |||||||
Packet Buffer | 4 M bit | |||||||
MAC | 16K | |||||||
Weight | 2.12KG | |||||||
Dimensions (W×D×H) | 440*195*44mm | |||||||
Power supply | AC: 100-240 V, 50/60 Hz | |||||||
Max.Power | 250W | |||||||
Max. PoE Power | Max capacity: 250 W, Max capacity for single port: 30 W | |||||||
Prior Ports | 1 to 8 | |||||||
Cooling Fans | 1 | |||||||
Mean Time Between Failure (MTBF) | >50000 hours | |||||||
Storage Temperature | -40 ℃ to 70 ℃ | |||||||
Operating temperature | 0 ℃ to 40 ℃ (32 ℉ to 104 ℉) | |||||||
Operating humidity | 10%~90% (non-condensing) | |||||||
Storage humidity | 5%~90% (non-condensing) | |||||||
Indicator | POWER Steady on: AC input is normal, POWER Off: No AC input, PoE Off: No PoE power supply, PoE Steady on: PoE power supply is normal, PoE-MAX off: The POE power supply power of the whole machine is less than 80% of the specification, PoE-MAX Steady on : The POE power supply power of the whole machine is greater than 85% of the specification, LINK/ACT Off: No link, LINK/ACT Steady on: Linked, LINK/ACT Flashing: Transmitting data | |||||||
Working Mode | Default (Normal mode) : All ports can communicate with each other, VLAN (Secure mode): Downlink ports can communicate only with uplink ports. Enabling PD keepalive function, the switch will restart the IPC via PoE power when the IPC sends no message in a period of time, Extend (Surveillance mode): Transmission distance up to 250 meters. Downlink ports can communicate only with uplink ports | |||||||
Sinrato Themes | 09/04/2019 |